error occurs when an observation is taken exactly at midnight UTC (00:00)....

error occurs when an observation is taken exactly at midnight UTC (00:00). This causes a problem to calculate the n value because hr and mi variables are empty. I made a quick fix by setting n value to 24 if an observation is taken at midnight.